运维开发网

solaris 消除告警信息

运维开发网 https://www.qedev.com 2020-04-30 09:13 出处:51CTO 作者:wukaiqiang28
->start/SP/faulttmgmt/shellstart:Invalidtarget/SP/faulttmgmt/shell->start/SP/faultmgmt/shellAreyousureyouwanttostart/SP/faultmgmt/shell(y/n)?yfaultmgmtsp>fmadmfaultyTimeUUIDmsgidSeverity2019-

-> start /SP/faulttmgmt/shell

start: Invalid target /SP/faulttmgmt/shell

-> start /SP/faultmgmt/shell

Are you sure you want to start /SP/faultmgmt/shell (y/n)? y

faultmgmtsp> fmadm faulty


Time UUID msgid Severity


2019-10-21/13:51:44 7d6be8a5-d27c-6e12-fd6b-b809cde44fe2 DISK-8000-0X Major

Fault class : fault.io.disk.predictive-failure

FRU : /SYS/MB/HDD0

(Part Number: )

(Serial Number: )

Description : A fault has been diagnosed by the Host Operating System.

Response : The service required LED on the chassis and on the affected

FRU may be illuminated.

Impact : No SP impact. Check the Host OS for more information.

Action : The administrator should review the fault on the Host OS.

Please refer to the Details section of the Knowledge Article

for additional information.


Time UUID msgid Severity


2019-06-25/17:30:25 4e46e6f2-66f8-c0d2-d9dc-f1558440291e DISK-8000-0X Major

Fault class : fault.io.disk.predictive-failure

FRU : /SYS/MB/HDD1

(Part Number: )

(Serial Number: )

Description : A fault has been diagnosed by the Host Operating System.

Response : The service required LED on the chassis and on the affected

FRU may be illuminated.

Impact : No SP impact. Check the Host OS for more information.

Action : The administrator should review the fault on the Host OS.

Please refer to the Details section of the Knowledge Article

for additional information.

faultmgmtsp> fmadm repair 7d6be8a5-d27c-6e12-fd6b-b809cde44fe2

faultmgmtsp> fmadm repair 4e46e6f2-66f8-c0d2-d9dc-f1558440291e

0